BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//ISA - Houston Section - ECPv6.15.18//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.houstonisa.org
X-WR-CALDESC:Events for ISA - Houston Section
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Chicago
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20200308T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20201101T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20210314T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20211107T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20220313T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20221106T070000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Chicago:20210913T080000
DTEND;TZID=America/Chicago:20211114T160000
DTSTAMP:20260406T163400
CREATED:20210728T172258Z
LAST-MODIFIED:20210728T172405Z
UID:10000029-1631520000-1636905600@www.houstonisa.org
SUMMARY:Using the ISA/IEC 62443 Standards to Secure Your Control Systems (IC32)
DESCRIPTION:Certification of Completion: A Certificate of Completion indicating the total number of CEUs earned will be provided upon successful completion of the course. \nCertificate Program: Part of the ISA/IEC 62443 Cybersecurity Certificate Program \nYour course registration includes your registration for the exam. \nDescription: \nThe move to using open standards such as Ethernet\, TCP/IP\, and web technologies in supervisory control and data acquisition (SCADA) and process control networks has begun to expose these systems to the same cyberattacks that have wreaked so much havoc on corporate information systems. This course provides a detailed look at how the ANSI/ISA99 standards can be used to protect your critical control systems. It also explores the procedural and technical differences between the security for traditional IT environments and those solutions appropriate for SCADA or plant floor environments. \nYou will be able to: \n\nDiscuss the principles behind creating an effective long term program security\nInterpret the ISA/IEC 62443 industrial security framework and apply them to your operation\nDefine the basics of risk and vulnerability analysis methodologies\nDescribe the principles of security policy development\nExplain the concepts of defense in depth and zone/conduit models of security\nAnalyze the current trends in industrial security incidents and methods hackers use to attack a system\nDefine the principles behind the key risk mitigation techniques\, including anti-virus and patch management\, firewalls\, and virtual private networks\n\nYou will cover: \n\nUnderstanding the Current Industrial Security Environment: What is Electronic Security for Industrial Automation and Control Systems? | How IT and the Plant Floor are Different and How They are the Same\nHow Cyberattacks Happen: Understanding the Threat Sources | The Steps to Successful Cyberattacks\nCreating A Security Program:  Critical Factors for Success/Understanding the ANSI/ISA-62443-2-1 (ANSI/ISA-99.02.01-2009)- Security for Industrial Automation and Control Systems: Establishing an Industrial Automation and Control Systems Security Program\nRisk Analysis:  Business Rationale | Risk Identification\, Classification\, and Assessment\nAddressing Risk with Security Policy\, Organization\, and Awareness: Cyber Security Management System Scope | Organizational Security | Staff Training and Security Awareness\nAddressing Risk with Selected Security Counter Measures: Personnel Security | Physical and Environmental Security | Network Segmentation | Access Control\nAddressing Risk with Implementation Measures: Risk Management and Implementation | System Development and Maintenance | Information and Document Management\nMonitoring and Improving the CSMS: Compliance and Review | Improve and Maintain the CSMS\nValidating or Verifying the Security of Systems: What is being done? | Developing Secure Products and Systems\n\nClassroom/Laboratory Demo: \n\nPCAP Live Capture Analysis\n\nIncludes ISA Standards: \n\nANSI/ISA-62443-1-1 (ANSI/ISA-99.00.01-2007)\, Security for Industrial Automation and Control Systems Part 1: Terminology\, Concepts & Models\nANSI/ISA-62443-2-1 (ANSI/ISA-99.02.01-2009)\, Security for Industrial Automation and Control Systems: Establishing an Industrial Automation and Control Systems Security Program\nANSI/ISA-62443-3-3\, Security for industrial automation and control systems: System security requirements and security levels\n\nRecommended Pre-Requisites: \nThere are no required prerequisites for taking this course; however\, it is highly recommended that applicants have at least one to three years of experience in the cybersecurity field with some experience in an industrial setting. \nISA Courses: TS06\, TS12\, or equivalent knowledge/experience would be beneficial. \nNote from the Instructor: One of the challenges I have had in teaching IC32 is students attending without any or limited knowledge of TS04\, TS06\, TS12 or cybersecurity general principles. IC32 is a 14-hour boot camp style class and there is not a lot of time to teach basic comms and cybersecurity. \nRecommended reading in preparation for course: \nCybersecurity Library \nWhich Security Level (SL) would have been required to prevent the attack? \nNot sure this particular course is for you? \nA pre-instructional survey is available for you to evaluate your level of understanding of the course material and to show you the types of questions you’ll be able to answer after completing the course.
URL:https://www.houstonisa.org/event/using-the-isa-iec-62443-standards-to-secure-your-control-systems-ic32-2/
LOCATION:Burns McDonnell\,1898 & Co.\, 1700 West Loop South\, Houston\, 77027\, United States
CATEGORIES:Training,Cyber-Security
ORGANIZER;CN="Glen Wood":MAILTO:glnwd15@gmail.com
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Chicago:20211018T080000
DTEND;TZID=America/Chicago:20211022T160000
DTSTAMP:20260406T163400
CREATED:20210728T174012Z
LAST-MODIFIED:20210728T174252Z
UID:10000135-1634544000-1634918400@www.houstonisa.org
SUMMARY:Safety Instrumented Systems: A Life-Cycle Approach (EC50)
DESCRIPTION:Certification of Completion: A Certificate of Completion indicating the total number of CEUs earned will be provided upon successful completion of the course. \nCourse and Certificate Program: This course is required for the ISA/IEC 61511 SIS Fundamentals Specialist Certificate Program \nYour course registration includes your registration for the exam. \nDescription: \nThis course focuses on the engineering requirements for the specification\, design\, analysis\, and justification of safety instrumented systems for the process industries. Students will learn how to determine safety integrity levels and evaluate whether proposed or existing systems meet the performance and documentation requirements defined in the ISA 84 (IEC61511) standard. \nThis course is required for the ISA/IEC 61511 SIS Fundamentals Specialist Certificate. When you register for the course\, the certificate exam is included with your registration. \nThose who successfully complete this course and pass the exam receive the designation of ISA/IEC 61511 SIS Fundamentals Specialist Certificate. \nYou will be able to: \n\nDifferentiate between process control and safety control\nImplement the ISA84 (IEC 61511) standard\nEvaluate process risk levels\nSelect Safety Integrity Levels (SILs) for Safety Instrumented Functions (SIFs) using a variety of techniques\nAnalyze the performance of different logic system technologies\nAnalyze the performance of various sensor\, logic\, and final element configurations\, as well as the impact of diagnostics\, test intervals\, common cause\, system size\, imperfect manual testing\, and bypassing\nDetermine optimum system test intervals\nSpecify and select safety instrumented systems\nApply the documentation requirements for process safety management\, regulations\, and industry standards\n\nYou will cover: \n\nIntroduction: Accidents and Resulting Regulations | Lessons Learned From Past Accidents | Standards & Guidelines of Interest\nScope & Safety Life Cycle: Management Issues | Design Life Cycle |\nSafety Layers: Independent Safety Layers | Separation of Control and Safety\nRisk\, Hazard Analysis\, Safety Integrity Levels: Hazard Identification | Risk Assessment | Selecting Safety Integrity Levels | Layer of Protection Analysis\nFailure Modes & Reliability Concepts: Safe vs. Dangerous | Failure Mode vs. Technology | Failure Rates | Modeling Techniques | Test Intervals | Fault Tolerance Requirements\nSystem Technologies: Pneumatic | Relay | Microprocessor | Field Devices | Certification | Prior Use\nSystem Design: Requirements Specification | General Design Issues (Environment\, Interfaces\, Bypasses\, Resets\, etc.)\nOperations and Maintenance: Installation | Operation & Maintenance | Testing | Management of Change | Decommissioning\n\nClassroom/Laboratory Exercises: \n“The lab sessions were very helpful. I was very pleased with the course. More so than any other technical course I have been to. I feel that I really learned something.” \n– Shawn Coughlan \n\nCalculate device failure rates\nModel system performance for relay and software-based logic systems\nModel the impact of different configurations\, field devices\, automatic diagnostics\, manual test intervals\, common cause\, and imperfect manual testing and bypassing\nDetermine the SIL (safety integrity level) of a sample functions and design a system to meet the performance requirements\nClassroom Copies of ISA/IEC 61511 standards will be provided for your use during the course\n\nA hand-held/scientific calculator should be brought to class. \nTextbook Included: \nSafety Instrumented Systems: A Life Cycle Approach\nBy Paul Gruhn\, PE\, CFSE and Simon Lucchini\, CFSE\, MIEAust CPEng \nNot sure this particular course is for you? \nA pre-instructional survey is available for you to evaluate your level of understanding of the course material and to show you the types of questions you’ll be able to answer after completing the course.
URL:https://www.houstonisa.org/event/safety-instrumented-systems-a-life-cycle-approach-ec50/
LOCATION:Kenexis\, 15995 N Barkers Lndg Rd Ste 143 Houston\, TX 77079-2418\, Houston\, TX\, 77079-2418\, United States
CATEGORIES:Training,Safety
ORGANIZER;CN="Glen Wood":MAILTO:glnwd15@gmail.com
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Chicago:20211020T080000
DTEND;TZID=America/Chicago:20211020T170000
DTSTAMP:20260406T163400
CREATED:20210708T191023Z
LAST-MODIFIED:20210803T152155Z
UID:10000027-1634716800-1634749200@www.houstonisa.org
SUMMARY:CSE Exam Study Group : Safety Systems Part 2
DESCRIPTION:Are you looking to take your PE Engineering Exam for the State of Texas in October? \nAre you looking for a Group to Study with?  HOUSTON ISA Section is your answer. \n  \nAll Future Control Systems PEs! \n  \nSign up quickly with ISA Houston Section which is offering a 10-session professional study group course to prepare you to pass the Control Systems Engineer (CSE) Professional Engineer (PE) examination in October. \n  \nThe course includes exam preparation materials that will be reviewed during each session with a knowledgeable facilitator. If you are a control systems professional in the Houston area and are planning to take the CSE exam\, follow this link to find out more information and register for the course.” \n  \nFor each session you want to attend you MUST sign up for that session. Also\, you must be a ISA member in good standing. These sessions are at no charge and are provided as a service from the ISA Houston Section. \n  \nIn order to receive the discount for ISA books\, you must register no later than July 31st. \n  \nFor questions on the CSE Exam Study Course please email  the assistant education chair\, Glen Wood\, at glnwd15@gmail.com
URL:https://www.houstonisa.org/event/cse-exam-study-group-safety-systems-part-2/
LOCATION:Vector\, 14517 Kirby Dr\, Pearland\, TX\, 77047\, United States
CATEGORIES:Training,Professional-Engineering
ORGANIZER;CN="Glen Wood":MAILTO:glnwd15@gmail.com
END:VEVENT
END:VCALENDAR